Passive Harmonic Filters

Enerdoor offers a selection of THDI solutions including line reactors and passive harmonic filters from 230 – 690Vac and reduces current THD to <5% with an unbalanced voltage of 2.5% .

Please note we are still adding products to our new website. Can't see the product you need? Contact us on 01444 243 452 / enquiries@gdrectifiers.co.uk

Expert technical support

Design Inspiration, whenever you need it

Custom & flexible ordering

Filter By

  • Filter By
    Filter By

     

    Manufacturer
    Voltage (Vac)
    Rated Current at 50°C (A)
    Rated Power 400Vac (kW)
    Industry
    Typical Applications
    Industry Approvals

Showing 1–20 of 53 results

Show:
Sort By:
    • Download Datasheet
    • Parts List
    • Compare
    • Download Datasheet
    • Parts List
    • Compare
    • Download Datasheet
    • Parts List
    • Compare
    • Download Datasheet
    • Parts List
    • Compare
    • Download Datasheet
    • Parts List
    • Compare
    • Download Datasheet
    • Parts List
    • Compare
    • Download Datasheet
    • Parts List
    • Compare
    • Download Datasheet
    • Parts List
    • Compare
    • Download Datasheet
    • Parts List
    • Compare
    • Download Datasheet
    • Parts List
    • Compare
    • Download Datasheet
    • Parts List
    • Compare
    • Download Datasheet
    • Parts List
    • Compare
    • Download Datasheet
    • Parts List
    • Compare
    • Download Datasheet
    • Parts List
    • Compare
    • Download Datasheet
    • Parts List
    • Compare
    • Download Datasheet
    • Parts List
    • Compare
    • Download Datasheet
    • Parts List
    • Compare
    • Download Datasheet
    • Parts List
    • Compare
    • Download Datasheet
    • Parts List
    • Compare
    • Download Datasheet
    • Parts List
    • Compare

Showing 1–20 of 53 results

We're here to help

Our engineering team are on hand to assist with technical support. We can work with you to develop a customised active harmonic filter for your application. Customised voltage, current, connection, and attenuation solutions are available to satisfy various application needs. Get in touch to discuss your requirements.

Contact us

Passive Harmonic Filters

Passive harmonic filters are currently the most commonly used method to control the flow of harmonic currents. Passive harmonic filtering solutions improve flicker emissions and reduce the effects of voltage dips under 5ms on the machine’s performance.

FINHRM5C is Enerdoor’s latest passive harmonic filter, the most advanced and smallest passive harmonic filter on the market.  It ensures IEEE-519 compliance, is UL recognised, and offers a current range up to 1400A.  The FINHRM5 offers a current range up to 800A and the FINHRM up to 200A. The typical THDI reduction is <5% for the FINHRM5/FINHRM5C and <15% for the FINHRM. Neither filter is effected by network impedance. This series is designed to guarantee a power factor greater than 0.9 considering an initial value of 0.7. An additional external capacitor to improve power factor correction may be included.

Enerdoor offers a range of passive harmonic filters for harmonic currents available up to 300A with voltage up to 480Vac. Together, Enerdoor and Finmotor have more than 20 years radio frequency interference experience and have developed the harmonic filter series to solve harmonic disturbance and power quality issues by compensating current harmonic and power factor correction.

Enerdoor Harmonic Filters by GD Rectifiers

The FINHRM and FINHRM2 passive harmonic filters offer different levels of attenuation to provide the market with the best compromise to meet the EN61000-3-2, EN61000-3-12 and IEEE519 International Standards. Custom harmonic filters are available for voltages up to 690Vac.

View Harmonic Filters Brochure

 

Part No.              Type         Rated Currents        Nominal Voltage     Characteristics   
FINFF 3% – 230 Vac           Line Reactor 3% 2.5 – 250A 230 Vac Frequency range 50-60Hz
FINFF 3% – 400 Vac Line Reactor 3% 1 – 865A 400 Vac Frequency range 50-60Hz
FINFF 3% – 480 Vac   Line Reactor 3% and 5% 1 – 750A 480 Vac Frequency range 50-60Hz
FINFF 5% – 230 Vac Line Reactor 3% and 5% 2.5 – 250A 230 Vac Frequency range 50-60Hz
FINFF 5% – 400 Vac Line Reactor 5% 1 – 865A 400 Vac Frequency range 50-60Hz
FINFF 5% – 480 Vac Line Reactor 3% and 5% 1 – 750A 480 Vac Frequency range 50-60 Hz
FINHRM Passive Harmonic 10 – 200A 480 Vac THDI reduction <15%, frequency range 50-60Hz
FINHRM5 Passive Harmonic 10 – 750A 480 Vac Current THD <5%, frequency range 50-60Hz
FINHRM5C Passive Harmonic 10 – 750A 480 Vac (HV version up to 690 Vac) Current THD <5%, frequency range 50-60Hz

 

For further information on harmonic filters, please contact us on 01444 243 452 or email enquiries@gdrectifiers.co.uk.

GD Rectifiers engineer reordering components.

Can't find what you're looking for?

We welcome the chance to beat your current prices by quoting you on volume orders, sourcing items from manufacturers extended ranges or those not currently in our product portfolio. We hold quotes for 30 days, protecting you against price increases.

Find out more

Get the Latest News from GD Rectifiers

Sign up for the latest products, offers and news. Read our Privacy Policy

Cookie Preferences

We use cookies and other technologies to improve your browsing experience on our website.
For more information, please visit our Privacy policy.